The default
SmartMesh IP
mote running in "Master" mode runs an application called "OAP". Talking to that application allows one to have the mote sample temperature, set the LED, etc. TheOapClient
sample application allows you to do that over the command line. It does similar things as the TempMonitor and PkGen app, but over a command line interface.Make sure that the motes you want to control with the OapClient
app are running the default
SmartMesh IP
firmware, in Master mode.
We assume that the motes are on and that the network is formed.
- start the application by double-clicking on
OapClient.py
connect to the manager using the following command. The application lists the motes currently operational.
> connect COM23 Operational motes: 0: 00-17-0d-00-00-38-05-da 1: 00-17-0d-00-00-38-03-ca 2: 00-17-0d-00-00-38-06-45 3: 00-17-0d-00-00-38-03-69 4: 00-17-0d-00-00-38-06-6a 5: 00-17-0d-00-00-38-04-35 6: 00-17-0d-00-00-38-07-18 Currently using mote 0 (00-17-0d-00-00-38-05-da). notifications are ON. logging to logfile is OFF.
The following are things you can do:
Getting help
The help
command lists the commands you can use:
Available commands: - help (h): print this menu - info (i): information about this application - quit (q): quit this application - uptime (ut): how long this application has been running - connect (c): connect to a serial port - motes (m): list all the nodes in the network - select (s): select the mote to use - notifs (n): toggle whether to print OAP notifications - writelogfile (w): toggle whether to write OAP notifications to a LOGFILE - led (l): set/clear blue led - temp (t): interact with the OAP "temp" resource - pkgen (p): set the pkgen application on the mote
Switching OAP notifications on/off
By default, the app prints every OIAP notification it receives. The notifs
commands toggles that on/off:
Received-Time = 1025666138.5 OAP notification from 00-17-0d-00-00-38-07-18: TEMP=2222 Received-Time = 1025666139.43 OAP notification from 00-17-0d-00-00-38-03-ca: TEMP=2521 Received-Time = 1025666139.43 OAP notification from 00-17-0d-00-00-38-03-69: TEMP=2458 Received-Time = 1025666142.42 OAP notification from 00-17-0d-00-00-38-06-6a: TEMP=1986 Received-Time = 1025666148.6 OAP notification from 00-17-0d-00-00-38-06-6a: TEMP=1986 Received-Time = 1025666152.72 OAP notification from 00-17-0d-00-00-38-06-6a: TEMP=1964 notifs notifications are OFF. > > notifs notifications are ON. > Received-Time = 1025666187.72 OAP notification from 00-17-0d-00-00-38-06-6a:TEMP=2007 Received-Time = 1025666190.96 OAP notification from 00-17-0d-00-00-38-04-35: TEMP=2650
List the motes in the network
motes Operational motes: 0: 00-17-0d-00-00-38-05-da 1: 00-17-0d-00-00-38-03-ca 2: 00-17-0d-00-00-38-06-45 3: 00-17-0d-00-00-38-03-69 4: 00-17-0d-00-00-38-06-6a 5: 00-17-0d-00-00-38-04-35 6: 00-17-0d-00-00-38-07-18
Switch LEDs on/off
> led 5 1 <blue LED on mote 00-17-0d-00-00-38-04-35 goes on> > led 5 0 <blue LED on mote 00-17-0d-00-00-38-04-35 goes on>
Interact with the temperature sensor
> Received-Time = 1025666400.97 OAP notification from 00-17-0d-00-00-38-04-35: TEMP=2542 > Received-Time = 1025666431.86 OAP notification from 00-17-0d-00-00-38-04-35: TEMP=2607 Received-Time = 1025666510.99 OAP notification from 00-17-0d-00-00-38-04-35: TEMP=2564 Received-Time = 1025666510.99 OAP notification from 00-17-0d-00-00-38-04-35: TEMP=2585 <one temperature reading every 30 s by default> > temp 5 1 1000 > Received-Time = 1025666551.28 OAP notification from 00-17-0d-00-00-38-04-35: TEMP=2585 Received-Time = 1025666555.05 OAP notification from 00-17-0d-00-00-38-04-35: TEMP=2628 Received-Time = 1025666555.22 OAP notification from 00-17-0d-00-00-38-04-35: TEMP=2585 Received-Time = 1025666555.4 OAP notification from 00-17-0d-00-00-38-04-35: TEMP=2564 <one temperature reading every 1 s> > temp 5 1 30000 <one temperature reading every 30 s>
Interact with the packet generator
Have mote 00-17-0d-00-00-38-04-35
send 10 packets, one every 100ms, filled with 15 bytes
> pkgen 0 10 100 15 > Received-Time = 1025666787.65 OAP notification from 00-17-0d-00-00-38-04-35: PKGEN pid=0 startPid=0 numPackets=10 Received-Time = 1025666787.85 OAP notification from 00-17-0d-00-00-38-04-35: PKGEN pid=1 startPid=0 numPackets=10 Received-Time = 1025666787.94 OAP notification from 00-17-0d-00-00-38-04-35: PKGEN pid=2 startPid=0 numPackets=10 Received-Time = 1025666788.04 OAP notification from 00-17-0d-00-00-38-04-35: PKGEN pid=3 startPid=0 numPackets=10 Received-Time = 1025666788.14 OAP notification from 00-17-0d-00-00-38-04-35: PKGEN pid=4 startPid=0 numPackets=10 Received-Time = 1025666788.6 OAP notification from 00-17-0d-00-00-38-04-35: PKGEN pid=5 startPid=0 numPackets=10 Received-Time = 1025666788.63 OAP notification from 00-17-0d-00-00-38-04-35: PKGEN pid=6 startPid=0 numPackets=10 Received-Time = 1025666788.67 OAP notification from 00-17-0d-00-00-38-04-35: PKGEN pid=7 startPid=0 numPackets=10 Received-Time = 1025666788.7 OAP notification from 00-17-0d-00-00-38-04-35: PKGEN pid=8 startPid=0 numPackets=10 Received-Time = 1025666788.74 OAP notification from 00-17-0d-00-00-38-04-35: PKGEN pid=9 startPid=0 numPackets=10