This section refers to the following sample application(s):

  • 03-radioTest

This application is new to OCSDK 1.2.0

The OCSDK stack provides APIs for testing the radio - they are typically used for top-level assembly testing and radio certification testing.  


The 03-radioTest Sample Application

The 03-radioTest application largely emulates the testing functions built into the stock mote firmware.  See the SmartMesh IP Mote CLI Guide for the meaning of the various arguments. Unlike the stock firmware, the sample does not require putting the mote into an explicit radiotest mode (via radiotest on) before issuing test commands.

The application provides 3 CLI functions (available by typing help) for radio testing:

  • testTx - start a transmit test (analogous to mote CLI command radiotest tx)
  • testRx - start a receive test (analogous to mote CLI command radiotest rx)  
  • stat - print out the results of a completed receive test (analogous to mote CLI command radiotest stat)

It also provides a reset command for easily resetting the part.

radioTest app, ver 1.2.0.1
SmartMesh IP stack, ver 1.4.1.8


> testtx
Usage: testtx <testType> <chanMask> <power> <stationId> <repeatCnt> ...
... <numSubtests> {<pkLen> <delay> ...}

> testtx 0 0x0001 8 255 100 1 100 1000
Test started...
>Tx completed

> testrx
Usage: testrx <chanMask> <time (s)> <stationId>
Channel mask is in hex, e.g. 0x0001 selects channel 0 (IEEE ch 11)

>testrx 0x0001 100 255
Starting rx on channel 0
Rx completed

> stat
Radio Test Statistics:
  OkCnt   : 99
  FailCnt : 1


> mshow rstat
  OkCnt   : 99
  FailCnt : 1
  AveRSSI : -55
  AveLQI  : 0

In addition to the stat command, the stack supports the mshow rstat command which prints RSSI and LQI in addition to the packet OK/Fail counts.

Implementation Details

The 03-radioTest sample application uses the Helper Modules to initialize the CLI Module and for interaction with the local interface. It passes JOIN_NO in the fJoin flag when initializing the local module in the loc_task_init() to prevent the local module from attempting to join, as the radio can only be tested when the mote is in either the idle or radioTest state.