Expected completion time of this lab: 

Excerpt

10 min

.


Table of Contents

Overview of Master/Slave modes

The default firmware on your SmartMesh IP Mote has two modes of operation:

...

 

 

master mode

slave mode

OAP

enabled

disabled

serial API

disabled

enabled

need an external microcontroller?

NO

YES

Switching your motes to slave mode

  • Connect your SmartMesh IP Manager to your computer using an interface board.

    Tip

    If you only have one interface board, simply switch the manager on without connecting it to your computer.


  • Switch your SmartMesh IP Manager on.
  • Connect a SmartMesh IP Mote to your computer using an interface board.
  • Open PuTTY, and connect to your mote’s CLI interface.
  • Switch on your mote. The banner appears:

    Code Block
    SmartMesh IP mote, ver 1.3.0.24 (0x400)
    >


    Note

    Since your mote is in master mode by default, it will join your SmartMesh IP Manager after a couple of seconds. This is OK.


  • On your mote’s CLI, enter the following command to see what mode your mote is in:

    Code Block
    > get mode


  • What mode is your mote currently in?

     

  • Enter the following command to switch to “slave” mode:

    Code Block
    > set mode slave


  • Power cycle the mote. When the banner appears, enter the command to see what mode the mote is in. What mode is your mote currently in?

  • Congratulations! You have switched your mote to slave mode.
Note

In slave mode , the mote does NOT attempt to join the network. You can verify that the mote is indeed in “Lost” state of the manager’s CLI:

Code Block
> login user
> sm
MAC MoteId State Nbrs Links Joins Age StateTime
00-17-0D-00-00-38-0F-B3 1 Oper 0 19 1 0 0-00:07:16
00-17-0D-00-00-60-05-69 2 Lost 1 14 1 92 0-00:00:32
Number of motes (max 33): Total 2, Live 1, Joining 0