Figure 3: The DC2274A SmartMesh IP USB Manager

If you installed the correct drivers, you only have to insert the USB port in your computer: The manager will power up and start creating a network automatically.

...

By default the manager is shipped with a well-known network ID and join key that your application will need to connect to its network, so you do not need to configure anything. However, it is useful to know about certain commands available through the CLI. These commands are presented in the next section, while relevant default values for its configuration parameters are listed in Table 4.

 

 

Parameter
Anchor
tab_defaultManagerValues
tab_defaultManagerValues
Comment
Default Value
netidNetwork ID1229
commjoinkeyCommon Join Key (hex)44 55 53 54 4E 45 54 57 4F 52 4B 53 52 4F 43 4B 
basebwBase bandwidth, i.e. period between packets [ms]9000

 

Table 4: Relevant factory default values for the SmartMesh IP Manager

...

  1. Just like with the mote, identify the correct serial port name and connect to the CLI with a serial terminal of your choice (again, see Table 1 for configuration details).
  2. Unlike the mote, you will first have to login to have access to the commands we want:

    login 
    Code Block
    languagetext
    titleLogin
    > login user
      
  3. You now have access to a wide range of commands, where the most interesting ones are shown below.

...