Figure 3: The DC2274A SmartMesh IP USB Manager
If you installed the correct drivers, you only have to insert the USB port in your computer: The manager will power up and start creating a network automatically.
...
By default the manager is shipped with a well-known network ID and join key that your application will need to connect to its network, so you do not need to configure anything. However, it is useful to know about certain commands available through the CLI. These commands are presented in the next section, while relevant default values for its configuration parameters are listed in Table 4.
Parameter
| Comment | Default Value | ||||||
---|---|---|---|---|---|---|---|---|
netid | Network ID | 1229 | ||||||
commjoinkey | Common Join Key (hex) | 44 55 53 54 4E 45 54 57 4F 52 4B 53 52 4F 43 4B | ||||||
basebw | Base bandwidth, i.e. period between packets [ms] | 9000 |
Table 4: Relevant factory default values for the SmartMesh IP Manager
...
- Just like with the mote, identify the correct serial port name and connect to the CLI with a serial terminal of your choice (again, see Table 1 for configuration details).
Unlike the mote, you will first have to login to have access to the commands we want:
loginCode Block language text title Login > login user
- You now have access to a wide range of commands, where the most interesting ones are shown below.
...